Chemical Plant Stainless Steel Piping

The field results comprise thirty-one (31) iso drawings and three hundred and eighty-two (382) contact point corrosion readings on A312 TP316L EFW stainless steel uninsulated and insulated piping, ranging from half inch (½”) outside diameter (O.D.) to twenty inches (20”) outside diameter (O.D.), with the largest inspection distances of two hundred and thirty-six inches (236 inches). The inspection aimed to detect the inside diameter (ID) corrosion due to dissimilar metals. VIR revealed that there was no interference by the weld to identify corrosion at the heat-affected zone or within the weld itself. Prior to awarding the work, the customer conducted a probability of detection blind test. Please refer to Figure 7.

Chemical Plant Stainless Steel Piping

Figure 7 . A new sixty-inch (60) pipe underwent examination and comparison with a pipe sample featuring a defect at the heat affected zone of the weld.

VIR Systems logo tm

Brian K. Beresford “Bear”

Sole Proprietor
(832) 943-0979

10 Rosalie Street
Shepherd, Texas 77371