Principles of Design
The VIR measurement data are interpreted to provide information related to the corrosion of the pipe without requiring destructive testing. This feature allows for the accumulation of VIR data from multiple points, enabling comprehensive corrosion monitoring and the ability to predict and prevent equipment failure through advanced data analysis techniques. The VIR System technology employs corrosion-resistant stainless-steel sensors housed within a self-contained unit that can be magnetically attached, clamped, or secured to the test object. Permanent sensors can also be installed using a stud welding technique or permanent adhesion through continuous and accurate corrosion monitoring, the system assists in scheduling maintenance and repairs before significant degradation occurs, thus avoiding unplanned downtime and extending the usable life of the equipment. The collected data is uploaded to a VIR Systems analysis program tailored to the customers’ requirements with a yearly flat software rate with unlimited company users.
The VIR systems can be performed while the plant is operational and the inspection procedure includes preparing two dime sized bare surface test areas for each sensor, verifying our nominal wall thickness with an ultra-sonic thickness reading and recording the ambient temperature of the vessel or pipe we are inspecting using a non-contact infrared thermometer, once these measurements are taken the VIR test is performed.
Under normal conditions if no verifiable flawless standard is available, the VIR method can be calibrated to the existing pipe itself. inspecting stainless steel piping would be used in a way like tubular eddy current inspections in which the piping is inspected against itself. Differences from one section of the piping to another will indicate flaws in the material. It is important that inspection points are equal distance from one another when using this method. Currently our equipment can reach a span between inspection ports up to eighty (80) feet.

Analysis Curves
The VIR measuring unit curves were developed using new standards. The curves are built by testing a flawless standard of the same material type and size as the material to be inspected in regular pre-determined intervals from 1” up to 960” between the two testing leads. The customer equipment is then tested and compared to the results from the known standard and then processed through our VIR software for the final numbers. We can determine if any discontinuities exist on the customer equipment.

Brian K. Beresford “Bear”
Sole Proprietor
(832) 943-0979
10 Rosalie Street
Shepherd, Texas 77371